Compare your copper-neutral construction with a CCA option, starting with resistance, copper use and material cost per cable kilometre.

Send your current cable drawing or wire arrangement. We will prepare a candidate wire specification, a cost-comparison basis and a sample plan.

  • Candidate wire specification
  • Cost comparison per cable kilometre
  • Sample and validation plan

Bare wire supply. Finished-cable approval follows the applicable project requirements.

On this page

Where the Wire Is Used

Concentric neutral wires around the phase conductor of a low-voltage cable.
View full-size illustration

The concentric neutral is formed from wires laid around the insulated core or core assembly, beneath the outer sheath. Raytron supplies the individual CCA wire for that construction. A CCA phase conductor is a separate design choice and must follow its own requirements.

ENEL Italian Type I illustration: aluminum phase, CCA neutral
  • Centre: aluminum phase conductor
  • Blue: insulation; dark blue: outer sheath
  • Outer wire layer: CCA neutral wires, copper directly on aluminum

Low-voltage cable conductors and insulation layers. The optional ENEL Type I copper equalizing tape is not shown.

EPM reference: CCA phase and CCA neutral
  • Centre: CCA phase conductor; phase requirements apply separately
  • Blue: insulation; dark blue: outer sheath
  • Outer wire layer: CCA neutral wires, copper directly on aluminum

Low-voltage cable conductors and insulation layers.

Single-wire section: a continuous copper layer surrounds the aluminum core, with the cladding, core and interface identified.

Wire specification

Aluminum-core CCA and aluminum-alloy-core wire are specified separately. Match the individual wire, its condition and guaranteed properties to the proposed cable construction.

A candidate wire specification defines diameter, core material, temper, copper content and its measurement basis, together with electrical and mechanical requirements.

Request a candidate wire specification

Compare the Cost per Cable Kilometre

Compare Your Copper and Candidate Wire Schemes

Use actual metallic area, or count × individual wire diameter. Prices are optional. Results compare wire material per cable kilometre; they do not include the complete cable.

The example uses nominal area as actual area. Conductivity, density and copper fraction are entered separately; update them with your material data.

Model, Units and Assumptions

All included parallel wires share one material and path factor. Individual metallic cross-sections exclude gaps; k is wire length / axial cable length. Complex layers or different wire paths need separate construction analysis.

100%IACS reference resistivity is 0.017241 Ω·mm²/m at 20°C. A = n × π × d² / 4; R20 = 1724.1 × k / (c × A); required c = 1724.1 × k / (A × Rmax). c is entered as a percentage number, such as 65, not 0.65.

Wire mass per cable km = A × k × density. Ideal component density = f × copper density + (1 − f) × core density. Copper weight fraction = f × copper density / ideal density. A measured total density is a separate mode; it does not establish an exact component mass split.

To convert a known copper weight fraction w to volume fraction: f = (w / copper density) / [(w / copper density) + ((1 − w) / core density)]. Use matching measured inputs or clearly labelled ideal parameters, not an inferred alloy grade.

Purchase mass = retained mass / utilization. Recurring wire cost = purchase mass × price per kg + only additional costs absent from that price. No automatic scrap credit, ampacity, fault capacity, temperature, lifetime, regulatory acceptance or promised saving is calculated.

Copper equalizing tape, terminations and contact contributions are excluded from the resistance model. Finished-cable measurement and project approval remain separate.

Calculated illustrations for the six listed CCA reference areas

Separate from the original specification: nominal area is treated as actual and k = 1. These are model estimates, not ENEL material-conductivity limits or Raytron wire grades. Scroll horizontally on small screens.

Calculated reference values — k = 1
Reference area (mm²)Maximum R20 (Ω/km)Estimated required %IACS
83.0869.97
221.1568.15
370.72764.10
520.52463.27
690.38764.57
1310.19368.19
What belongs in the comparison

Copper use

Compare the copper contained in the complete proposed wire construction, not just the price per kilogram of CCA.

Resistance and space

Select wire area, count and lay geometry together. Keeping the same diameter does not ensure the same resistance.

Production and connection

Define payoff, bending, copper coverage and termination requirements before the wire trial.

Wire inspection

Wire inspection covers dimensions, copper-layer continuity, electrical resistance and mechanical properties against the selected specification.

Discuss inspection requirements

Wire inspection and finished-cable qualification address different requirements: material properties, cable processing, connections and service duty.

Utility Documents Worth Checking

LV concentric-conductor specification

ENEL — Italy

GSCC014 · Rev.00 — Amendment 01/2025

The 01/2025 amendment includes CCA concentric conductors for Italian Type I–III low-voltage cables. Confirm the specified construction and resistance for your project. The equalizing tape remains annealed copper: required for Types II–III and optional for Type I.

Combined PDF pp. 55, 59–60; §5.5 and Table 4.1 (amendment pp. 5–6)

Read the source: GSCC014 Rev.00 — Amendment 01/2025

Published 2018 service-cable reference

Grupo EPM — Colombia

ET-TD-ME01-18 · Rev.2 — published 2018

The published Rev.2 describes 1×6+6 AWG and 2×6+6 AWG concentric service cables, 600 V, 90°C, XLPE/XLPE, with CCA phase and neutral conductors. Check the CENS catalogue and confirm the controlled issue required for a new project.

PDF pp. 1–2: revision; p. 6: cable configurations and conductor positions

Read the source: ET-TD-ME01-18 Rev.2 — published 2018

Check ET-TD-ME01-18 in the CENS catalogue

The source documents define the cable constructions and material requirements covered by each reference.

Start with the Resistance Target

Use the reference table below to identify a design target, then confirm the actual wire area and lay geometry. The values describe the concentric conductor defined in the cited specification.

Reference cable requirements — not Raytron wire grades.

Source specification values: GSCC014 Rev.00 — Amendment 01/2025, Table 4.1 · PDF p. 60
Copper nominal area mm²CCA nominal area mm²Min. copper wiresMin. CCA wiresMin. wire diameter mmMax. conductor resistance at 20°C Ω/kmInquiry reference
6818120.53.08 Use as an inquiry reference
10Not listed18Not listed0.61.83 Not listed
162218160.71.15 Use as an inquiry reference
25372028Not specified0.727 Use as an inquiry reference
35523039Not specified0.524 Use as an inquiry reference
50693554Not specified0.387 Use as an inquiry reference
951314550Not specified0.193 Use as an inquiry reference

Scroll the table horizontally. “Not listed” means no option is listed; “Not specified” means the source gives no value. Neither means zero.

How to read minimum counts, diameter and nominal area

Minimum wire count and minimum diameter are separate constraints. Twelve 0.5 mm wires have a total metallic area of about 2.356 mm², not 8 mm². Nominal area is not measured metallic area.

From drawing review to cable validation

  1. 1. Drawing and cost review

    Your team
    Current copper-wire arrangement or drawing, target market, known resistance and quantity.
    Raytron technical support
    Candidate wire specification, resistance and mass comparison, and a sample trial proposal.
    Next stage
    Agree the application, candidate material and sample task before ordering a trial.
  2. 2. Wire and machine trial

    Your team
    Agree trial quantity, spool, process checks and the cable-machine trial owner.
    Raytron technical support
    Agree inspection items, sample charges, responsibilities and the adjustment route if a trial does not meet the agreed requirements.
    Next stage
    Meet the agreed wire and processing criteria. Wire results alone do not release a finished cable.
  3. 3. Cable and accessory validation

    Your team
    Cable maker and project parties confirm fault, connection and environmental test scope, institution, costs and release owner.
    Raytron technical support
    Provide the agreed material inputs for the project validation plan.
    Next stage
    The responsible project parties approve the finished-cable and accessory evidence; timing is agreed per project.

Samples and supply conditions

The quotation sets sample quantity, charges, packaging, delivery and joint requirements for the selected wire specification.

Discuss sample quantity and supply conditions

Agree laboratory samples, machine trials and production orders separately. Validation responsibilities, costs and timing are confirmed with the project parties.

Detailed wire-trial inputs

Define the Wire Trial

Cable requirement
Target market, utility or customer specification, voltage and reference revision
Wire construction
Diameter, tolerance, number of wires and proposed lay
Electrical target
Conductor resistance at 20°C and the required material conductivity, when known
Material
Copper fraction by volume or weight, core material and temper
Trial and supply
Trial quantity, expected demand, spool and payoff requirements

Raytron prepares a proposed wire specification, sample-inspection scope and quotation basis for agreement with your team. Sample inspection may cover agreed dimensions, copper-layer cross-sections, electrical and mechanical properties. Finished-cable and accessory tests are assigned with the cable manufacturer.

Share the drawing-review checklist with your team

These two-page checklists cover inquiry inputs, model assumptions, inspection methods, trial steps and project responsibilities.

LV inquiry and validation checklist · PDF, 2 pages

Common Questions

Can I start with my existing copper-wire drawing?

Yes. Send the drawing and the target market. Add the required resistance and trial quantity if available; we can compare conductor options for the design.

Do you supply the finished insulated cable?

Raytron supplies bare CCA wire for cable manufacturers. The cable manufacturer designs and qualifies the finished insulated cable.

Does the ENEL table require every CCA grade to be at least 70% IACS?

No. The table specifies conductor construction and maximum resistance. A material-conductivity estimate also depends on actual metallic area and wire length in the cable.

Can CCA replace the copper neutral without changing its dimensions?

Not as a general rule. Compare the required resistance, available space, wire count and lay before selecting the diameter.

What does the EPM reference cover?

ET-TD-ME01-18 Revision 2 (2018) describes the cited LV concentric service-cable constructions. Use the document issue specified for your project.

What is enough for an initial inquiry?

Send your target market, current cable designation or drawing, known electrical requirements and expected quantity. Our technical team can review the conductor design and sample requirements.

Start with your copper-wire drawing

Choose a quotation, a sample request or a specification recommendation. Add the drawing and details you have in the shared inquiry form.

The inquiry form accepts one drawing or specification up to 20 MB. File content and type are checked before notification. Keep source requirements separate from your calculated scheme and project inputs.

Email and WhatsApp open a draft; you decide what to attach and send.

Raytron — Engineering Every Micron.

RFQ Request Quote Discuss your specification WhatsApp
Request Quote WhatsApp