Nickel-Clad Copper Ribbon Wire
NCC ribbon wire provides a narrow, flat copper conductor with a nickel outer layer. Specify width, thickness, edge condition and layer construction for the electronic part or miniature winding. Include resistance, joining and service-environment requirements.
View specificationsRequest QuoteOn this page
Connect the nickel layer to the ribbon duty
Nickel-clad copper ribbon places a nickel surface around a copper conductor for a defined lead, winding or connection. It differs from a pure nickel ribbon and from a nickel-plated copper ribbon.
Specify the layer construction and thickness basis together with bare geometry, edges, winding direction and connection process. Keep surface exposure, cut ends and joint temperature in the same component review.
Review nickel-layer constructionConstruction and specification
Scroll horizontally to read all columns.
| Item | Specification |
|---|---|
| Material | Nickel Clad Copper (Ni/Cu) |
| Product form | Ribbon wire |
| Electrical specification | A copper current path with a nickel surface for the designed connection and environment |
Specification design factors
Drawing-defined specification
Geometry and performance
- Width, thickness and edge geometry define a narrow flat conductor.
- Metal layers and solder or insulation coatings perform different functions.
- Spool format, winding tension and joining behavior connect the material to the assembly process.
Define width, thickness, nickel-layer construction, ratio basis, edge condition and temper. Include the joining method, bend duty, operating environment and acceptance tests.
Specifications and Documentation
Identify the product form, standard and edition required by the drawing. A material standard does not establish approval for the finished assembly. Agree inspection methods, acceptance limits and required documents for the order.
PV ribbon specifications separate the metallic conductor section from the solder coating. Cell layout, wire positioning, joining and module tests describe the intended interconnection.
View standards references · Review documentation requirements
Product questions
How does a flat section behave in bending and winding?
Width, thickness and corner geometry define the conductor envelope. Bending about the long and short edges produces different strains and springback. Bare metal and insulated finished dimensions occupy different portions of the available winding space.
What defines the nickel surface at the connection?
The layer construction, thickness by face or stated proportion, surface condition and any exposed cut edge describe the contact surface. Mating material, joint geometry and joining process define the connection test.
How are width and thickness related to the finished part?
The drawing pairs width and thickness and identifies corners, edge condition and temper. Separate width and thickness limits do not establish every combination. A coating or insulation build is recorded separately from the bare metal section.
Prepare your inquiry
- Width, thickness and tolerances
- Edge condition, burr, surface and roll dimensions
- Core and outer-layer metals, each layer or ratio, and mass or volume basis
- Surface finish or coating, joining method and inspection requirements
- Quantity, spool or coil format, packaging and delivery destination