Copper-Clad and Galvanized Steel Wire
Compare the required electrical duty, strength, outer-layer construction and exposure conditions, using the connection and installation requirements of the project.
Specify the core and outer layer of the wire
A copper layer and a zinc coating serve different surface functions. Identify core grade, wire diameter, layer construction, resistance and tensile properties before comparing the wire specimens.
Check the proposed connection and exposure together with layer thickness or coverage. A similar metallic appearance does not establish an identical coating or bonding process.
CCS round-wire specificationEngineering comparison
Scroll horizontally to view all columns.
| Decision | CCS round wire | galvanized steel wire | Comparison conditions |
|---|---|---|---|
| Surface system | Copper surface over a steel core | Zinc coating over a steel core | Define core grade, surface thickness and coating condition. |
| Design duty | Evaluate both current path and steel-core mechanical duty | Evaluate mechanical duty and electrical duty for the coated steel construction | Do not infer grounding-conductor or electrode equivalence from the steel core. |
| Exposure | Check copper damage, cut ends and dissimilar-metal joints | Check zinc damage, cut ends and dissimilar-metal joints | Use site exposure and installation-specific acceptance; no universal soil life is claimed. |
| References | Select B227 or B452 only for the applicable round CCS construction and purpose | Select the applicable galvanized-steel purchase specification | Keep electrical, mechanical and coating tests distinct. |
Copper-Clad and Galvanized Steel Wire: comparison record — open worksheet
Record your project requirements and observations, then download or include them in an inquiry.
| Item | Information / units | Your input |
|---|---|---|
| Comparison basis | Choose a common basis; no automatic equivalence is inferred | |
| Baseline and candidate | Materials, construction, form and drawing revisions | |
| Surface system | Copper surface over a steel core | Zinc coating over a steel core · Define core grade, surface thickness and coating condition. | |
| Design duty | Evaluate both current path and steel-core mechanical duty | Evaluate mechanical duty and electrical duty for the coated steel construction · Do not infer grounding-conductor or electrode equivalence from the steel core. | |
| Exposure | Check copper damage, cut ends and dissimilar-metal joints | Check zinc damage, cut ends and dissimilar-metal joints · Use site exposure and installation-specific acceptance; no universal soil life is claimed. | |
| References | Select B227 or B452 only for the applicable round CCS construction and purpose | Select the applicable galvanized-steel purchase specification · Keep electrical, mechanical and coating tests distinct. | |
| Methods, conditions and evidence | Units, test conditions, result source and reviewer |
Other formats and preview
Save or restore a draft
Drafts stay in this browser. Clear inputs also removes the saved draft.
Worksheet version: RT-RFQ-WORKSHEET-1.
Products and specifications
Include the drawing, intended application and acceptance criteria when requesting a comparison.
Send the wire and installation requirements